Edge Wound DC Load Bank Transformer Neutral Grounding Resistor

Product Details
Customization: Available
Resistance: Fixed Resistor
Function for Resistance: Protective Resistor, Load Resistor
Still deciding? Get samples of US$ 24.9/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2007-04-17
Type of Ownership
Limited Company
  • Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
  • Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
  • Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
  • Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
  • Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
  • Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
Find Similar Products

Basic Info.

Model NO.
REWR-G Series size2
Installation
Assemble
Material
Element
Packaging
Carton
Type
Edge-Wound Resistor
Quantity
Single Connection
Shape
Circular
Resistance change scale
Linear Scale
Application
Wind Power Generation
Brand
Power Electrie
Certificate
ISO9001
Temperature Rise
20ºC-375ºC
Terminal Tensile Strength
45n, 30s
Terminal Shock
Pr, 30min/-55ºC, 15min
Overload
10pr, 5s
Transport Package
Carton Packing
Specification
228.6mm
Trademark
Anhui Power Electrie
Origin
Bengbu, Anhui
HS Code
8533900000
Production Capacity
100000PCS/Year

Packaging & Delivery

Package Size
45.00cm * 35.00cm * 16.00cm
Package Gross Weight
15.000kg

Product Description

/ Product Characteristics /

Edge Wound DC Load Bank Transformer Neutral Grounding Resistor

 

/ Outline(mm) /


Edge Wound DC Load Bank Transformer Neutral Grounding Resistor


/ Dimecsions(in./mm)  /
 
Size A Over-all Dimensions
mm inch mm inch
2 228.6 9 177.8 7
3 285.75 11.25 254 10
4 381 15 330.2 13
5 438.15 17.25 406.4 16
6 615.95 24.25 457.2 18
7 615.95 24.25 558.8 22
8 762 30 635 25
9 838.2 33 711.2 28


/ Derating Curve /

Edge Wound DC Load Bank Transformer Neutral Grounding Resistor



 
/ Standard Bracket & Dimensions /
 
Size 2 3 4 5 6 7 8 9
Demensions mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch
A 228.6 9 304.8 12 381.0 15 457.2 18 508 20 609.6 24 685.8 27 762 30
B 203.2 8 279.4 11 355.6 14 431.8 17 482.6 19 584.2 23 660.4 26 736.6 29


{ BI Bracket Assembly Option & Dimention }

Edge Wound DC Load Bank Transformer Neutral Grounding Resistor

{ B2 Bracket Assembly Option & Dimension }


Edge Wound DC Load Bank Transformer Neutral Grounding Resistor

{ B3 Bracket Assembly Option & Dimension }

Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
 

/ Technical  Specifications /
 
Test ilerm Specifications Test Methods
Temperature Δ≤±5% 20ºC-375ºC
Terminal tensile strength Δ≤±(2%R+0.05Ω) 45N,30S
Terminal shock Δ≤±(2%R+0.05Ω) PR,30min/-55ºC,15min
Overload Δ≤±(2%R+0.05Ω) 10PR.5S
 

/ Type and Standard Resistance /
 
Rated current(A) Resistance Value(Ω)                        40ºC±10%
Size2 Size3 Size4 Size5 Size6 Size7 Size8 Size9
11 2.30 3.70 5.10 6.50 7.90 9.30 10.7 12.0
12 1.90 3.10 4.30 5.40 6.60 7.80 8.90 10.0
18 1.10 1.70 2.40 3.00 3.60 4.30 4.90 5.50
21 0.79 1.26 1.73 2.20 2.67 3.14 3.60 4.10
24 0.62 1.00 1.40 1.75 2.10 2.50 2.87 3.20
27 0.50 0.80 1.10 1.40 1.70 2.00 2.30 2.60
29 0.44 0.70 0.96 1.20 1.50 1.70 1.95 2.20
35 0.31 0.50 0.69 0.88 1.10 1.30 1.50 1.70
40 0.24 0.39 0.54 0.68 0.83 0.97 1.12 1.30
45 0.22 0.35 0.46 0.61 0.74 0.87 1.00 1.10
50 0.17 0.27 0.37 0.47 0.57 0.67 0.77 0.87
60   0.20 0.27 0.33 0.40 0.47 0.58 0.65
70   0.15 0.20 0.25 0.30 0.35 0.40 0.45
85   0.12 0.15 0.18 0.23 0.27 0.31 0.35
105   0.09 0.12 0.15 0.18 0.21 0.24 0.27
 
 
/ Product Display /


Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
/ F&Q /
Q:How can I place order?
A:You can contact us by email about your order details, or place order on line.


Q: How long is the lead time of orders?
A: Lead time: within 15-35 days after receive the deposit.

Q: What is your trade assurance?
A: 100% product quality protection.
100% product on time shipment protection.

Q: Do you make customized product?
A: Yes, we accept it.

Q: What should I do if I'm not satisfied with your product?
A: If there are defects in its quality, we can exchange a good one for you.
Generally, this problem is rare.

Q: What is the payment term?
A: T/T and Paypal is used more, please contact us for details.

Q: What is the quality level of your product?
A: We produce good quality, refuse to produce low quality.

 
Our products have been sold across
the country and in international markets
such as the United States, Canada, India and Israel.
Edge Wound DC Load Bank Transformer Neutral Grounding Resistor

WELCOME TO CONTACT  US  
We will do best to help you
 
Packed with thin film, pearl cottom and finally wooden case to protect the products well during transportation

Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
Edge Wound DC Load Bank Transformer Neutral Grounding Resistor
      

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier